LC1D115M7

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Taiwan

  • Validity to:

    Long-term effective

  • Last update:

    2023-09-11 06:03

  • Browse the number:

    329

Send an inquiries

Company Profile

RST Electric Industry Co., Ltd.

By certification [File Integrity]

Contact:yuchichang(Mr.)  

Email:

Telephone:

Phone:

Area:Taiwan

Address:Taiwan

Website:http://www.tw-rstpower.com/ http://yuchichang.hzxymbj.com/

Product details

Schneider ac magnetic contactor LC1D115M7 115A 220VAC 3P

 

 

Introduction

 

LC1D115M7 contactor is designed to effortlessly control a wide range of electrical devices, from small motors to large industrial machines.

 

Its robust design and premium build quality ensure exceptional performance and durability even in harsh environments.

Features

 

 

 

Products Description

 

Range of product
TeSys D
Product or component type
Contactor
Device short name
LC1D
Contactor application
Motor control
Resistive load
Utilisation category
AC-1
AC-3
Poles description
3P
Power pole contact composition
3 NO
[Ue] rated operational voltage
<= 300 V DC for power circuit
<= 1000 V AC 25...400 Hz for power circuit
[Ie] rated operational current
115 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
Motor power kW
65 kW at 1000 V AC 50/60 Hz
80 kW at 660...690 V AC 50/60 Hz
75 kW at 500 V AC 50/60 Hz
59 kW at 415...440 V AC 50/60 Hz
55 kW at 380...400 V AC 50/60 Hz
30 kW at 220...230 V AC 50/60 Hz
Motor power HP (UL / CSA)
100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors

Control circuit type

AC 50/60 Hz
Control circuit voltage
220 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
Overvoltage category
III
[Ith] conventional free air thermal current
200 A at <= 60 °C for power circuit
Irms rated making capacity
1260 A at 440 V for power circuit conforming to IEC 60947
250 A DC for signalling circuit conforming to IEC 60947-5-1
140 A AC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current
140 A 100 ms signalling circuit
120 A 500 ms signalling circuit
100 A 1 s signalling circuit
1100 A <= 40 °C 1 s power circuit
950 A <= 40 °C 10 s power circuit
550 A <= 40 °C 1 min power circuit
250 A <= 40 °C 10 min power circuit
Associated fuse rating
10 A gG for signalling circuit
200 A gG at <= 690 V coordination type 2 for power circuit
250 A gG at <= 690 V coordination type 1 for power circuit
Average impedance
0.60 mOhm at 50 Hz - Ith 200 A for power circuit
[Ui] rated insulation voltage
1000 V for power circuit conforming to IEC 60947-4-1
600 V for signalling circuit certifications UL
600 V for signalling circuit certifications CSA
690 V for signalling circuit conforming to IEC 60947-1
600 V for power circuit certifications UL
600 V for power circuit certifications CSA
Electrical durability
0.95 Mcycles 115 A AC-3 at Ue <= 440 V
0.8 Mcycles 200 A AC-1 at Ue <= 440 V
Power dissipation per pole
7.9 W AC-3
24 W AC-1
Safety cover
With
Mounting support
Plate
Rail
Standards
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
CSA C22.2 No 14
Product certifications
BV
CCC
CSA
DNV
GL
GOST
RINA
UL
LROS
Connections - terminals
Power circuit: connector 2 cable(s) 10...50 mm² - cable stiffness: solid - without cable end
Power circuit: connector 1 cable(s) 10...120 mm² - cable stiffness: solid - without cable end
Power circuit: connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - with cable end
Power circuit: connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - with cable end
Power circuit: connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - without cable end
Power circuit: connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable end
Control circuit: screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable end
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
Tightening torque
Power circuit: 12 N.m - on connector hexagonal 4 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Operating time
20...50 ms closing
6...20 ms opening
Safety reliability level
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
Mechanical durability
8 Mcycles
Operating rate
2400 cyc/h at <= 60 °C

 

 

Certification

 

Certificate of Authorized Distributor of Schneider Electrics

 

 

UL certificate for Schneider Electrics 

 

 

TAF certification for Schneider Electrics

 

 

Shipping Method

 

DHL Express

3~7 days delivery

FEDEX Express

3~7 days delivery

AIR Transport

Heavy cargo ship via air with high efficiency.

OCEAN Transport

Heavy cargo ship via sea with competitiive shipping cost.

 

 

Payment Method

 

1

Wire Transfer (T/T)

2

PayPal / Alipay

3

West Union

http://www.tw-rstpower.com/